Technical Details

Item Measurement Input and output connectors RCA/phono sockets, hard gold plated Input sensitivity range 1.6mV to 9.2mV (recommended) Output range (for above inputs) 179mV to 1030mV Maximum input 46mV rms Maximum output 5.2V rms Gain 41dB (112) at 1kHz Input impedance 47k Ohms plus 100pF Output impedance (driving impedance) 1k Ohm (will drive 10k

2017-10-27T11:35:18+00:00

Using Moving Coil Cartridges

Conventional (or low-output) moving coil cartridges output around one tenth of those of 'MM sensitivity.' The Reflex M can be used in conjunction with a step-up transformer or even better, the Elevator EXP step-up amplifier, to allow you to use moving coil cartridges. Alternatively a dedicated MC phono preamp such as the Reflex C may be used.

2017-10-27T11:35:36+00:00

Suitable Cartridges

Moving magnet (MM); high-output moving coil (HOMC); high output moving iron (MI) - in the output range: 1.6 - 9.2 mV (ref 1kHz at 5cm/sec) Your amplifier's volume control is intended to be set to give you the loudness you want and should be adjusted accordingly. With the lowest output cartridges you will need